Home > Wnetaddconnection2 Error > Wnetaddconnection2 Error 1202

Wnetaddconnection2 Error 1202

clearing up a few gigabytes and restarting the samba server fixed the problem. Sign in using Search within: Articles Quick Answers Messages Use my saved content filters home articles Chapters and Sections> Search Latest Articles Latest Tips/Tricks Top Articles Beginner Articles Technical Blogs Posting/Update Windows Vista:  This value is supported on Windows Vista and later.   Return value If the function succeeds, the return value is NO_ERROR. The select-by-location tool of ArcMap won't work properly! navigate here

I didn't see it while in full debug mode, and found it only when I changed to Plan C to write the net use statements out to a .bat file to Here are the (presumed relevant) code snippets I lifted from the original and adjusted a little -- Public Structure NETRESOURCE Public dwScope As Integer Public dwType As Integer Public dwDisplayType As I had disconnected a device from the gui, but the device name was "already in use". –Stefanos Kalantzis Mar 15 '12 at 13:36 thanks dekyos, this helped me too ERROR_CANNOT_OPEN_PROFILE The system is unable to open the user profile to process persistent connections.

If the lpLocalName member of NETRESOURCE specifies a local device to redirect, this flag has no effect, because the operating system still attempts to redirect the specified device. Linux questions C# questions ASP.NET questions fabric questions SQL questions discussionsforums All Message Boards... Any help in spotting my logic, typographical, etc., errors would be greatly appreciated.

It may be specific to a network provider. But the next map will bring me the error 1202 - ERROR_DEVICE_ALREADY_REMEMBERED when the same driver letter is used. Feb 1 '11 at 14:30 @Jeff: exactly, also not clear for me –Tim Feb 1 '11 at 14:34 @Tim silly question: Have you rebooted? Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies

Other possibilities are UAC blocking, have you tried running your app as Administrator? >>>>> Search First!!! <<<<< * How to get EFFECTIVE help: The Hitchhiker's Guide to Getting Help at VBF For example, for the following IPv6 address: 2001:4898:9:3:c069:aa97:fe76:2449 an example for a share might be the following: \\2001-4898-9-3-c069-aa97-fe76-2449.ipv6-literal.net\share Other network providers may support the lpRemoteName member of the NETRESOURCE structure pointed Thanks! .net winapi share|improve this question asked May 10 '10 at 21:17 Don 50911231 add a comment| 1 Answer 1 active oldest votes up vote 1 down vote accepted Don't include https://social.msdn.microsoft.com/Forums/en-US/ee7bd097-f4d8-4936-ba0c-1b694e35b90b/mapping-and-restoring-a-network-drive-in-vbnet?forum=netfxnetcom As the 6-dimensional mathematics professor said to the brain surgeon, "It ain't Rocket Science!" Reviews: "dunfiddlin likes his DataTables" - jmcilhinney Please be aware that whilst I will read private messages

You can do it under "Network and Sharing Center" from the start menu and then click on the Public icon to change it back to Work. If it still does not work, disconnect all mapped drives either from GUI or better from command line as in the previous post, delete the reg key above and then log If I manually delete the ( \\poplar\bpettis ) drive and manually remap it, then the routine "Temp" will execute fine and then it'll error again on the next run.4. How much more than my mortgage should I charge for rent?

During troubleshooting i found out that the root of the issue could be one of the assigned server IP's. view publisher site Advanced Search VBForums Visual Basic Visual Basic .NET [RESOLVED] Problem Mapping Drive on W7 If this is your first visit, be sure to check out the FAQ by clicking the link CONNECT_CURRENT_MEDIA 0x00000200 If this flag is set, then the operating system does not start to use a new media to try to establish the connection (initiate a new dial up connection, There's too much code, you don't know what all of it does, how would such a change even work?

See more: VC6 C++ Hi, I was doing remote system file access (i.e., Writing a file in remote machine & reading the same file from that machine). check over here How to route a wide groove in 2x2? lpUsername [in] A pointer to a constant null-terminated string that specifies a user name for making the connection. This value is returned if the lpRemoteName member of the NETRESOURCE structure pointed to by the lpNetResource parameter specifies a resource that is not acceptable to any network resource provider, either

Values for the four parameters passed into the MapDrive function are typically -- -- DriveLetter .. If lpProvider is NULL, or if it points to an empty string, the operating system attempts to determine the correct provider by parsing the string pointed to by the lpRemoteName member. Step 5: Test, Test, Test, and Test Again Step 6: Track Your Work! his comment is here more hot questions question feed default about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation

Requirements Minimum supported client Windows 2000 Professional [desktop apps only] Minimum supported server Windows 2000 Server [desktop apps only] Header Winnetwk.h Library Mpr.lib DLL Mpr.dll Unicode and ANSI names WNetAddConnection2W (Unicode) and WNetAddConnection2A Drives were set up with no credentials and there were no duplicate mappings. All rights reserved.800 East 96th Street, Indianapolis, Indiana 46240 To use Google Groups Discussions, please enable JavaScript in your browser settings and then refresh this page. .

How to delete all ._ files?

Reply With Quote Jun 3rd, 2013,01:07 PM #7 jtroan View Profile View Forum Posts Thread Starter New Member Join Date May 2013 Posts 9 Re: Problem Mapping Drive on W7 Thanks Thanks & regards, Yugeshkumar V Posted 18-Dec-11 21:53pm IT-NEWBIE595 Add a Solution 1 solution Rate this: Please Sign up or sign in to vote. CONNECT_COMMANDLINE 0x00000800 If this flag is set, the operating system prompts the user for authentication using the command line instead of a graphical user interface (GUI). This also affects the way that the WNetAddConnection2 function should be declared.

Feb 1 '11 at 14:43 | show 9 more comments 10 Answers 10 active oldest votes up vote 17 down vote You need to remap the drive. ValueMeaning CONNECT_UPDATE_PROFILE 0x00000001 The network resource connection should be remembered. I've lifted a lot of the drive-mapping code from the original VB source, but am having problems getting the drives to map. weblink We changed the drive letter to something that was not being used in Disk Management.

Log off and then log on. If this member is not NULL, the operating system attempts to make a connection only to the named network provider. It wasn't in any layer of the function calls I was doing..... This error is returned if the lpLocalName member of the NETRESOURCE structure pointed to by the lpNetResource parameter specifies a device that is not redirectable.

If lpPassword points to an empty string, the function does not use a password. ERROR_BAD_DEV_TYPE The type of local device and the type of network resource do not match. This error is returned if no network provider recognized the lpRemoteName member of the NETRESOURCE structure pointed to by the lpNetResource parameter. On the initial execution of the "Temp" routine all works as planned.

Maybe playing around with the input? This flag is also ignored unless you set the CONNECT_COMMANDLINE flag. Windows Server 2003 and Windows XP:  When the system automatically assigns network drive letters, letters are assigned beginning with Z:, then Y:, and ending with C:. I'll try doing a more indepth study of the WNetAddConnection3 function to see about using it. | Post Points: 5 Metallisoft Media, PA (Philadelphia) Since 6/16/2003 Posts 7,113 Reputation 45,010 Reply