Home > Wmi Error > Wmi Network Error

Wmi Network Error

Contents

WMI consumes a large amount of memory on my Windows Server 2008 R2 – what can I do? I moved that WF1 device+sensors to the root probe (MON2) here in my home office and the device and all sensors worked via IP. I have tried a WMI troubleshooting and everything is ok. The monitored machine is not able to connect to the Primary Domain Controller thus unable to verify the Windows credits provided for the WMI sensor.

I had been struggling for ages with a server that just suddenly stopped responding to WMI. Well, as we noted, there are some risks inherent in rebuilding the Repository. You can find an overview under PRTG WMI error messages Errors in the 800xxxxx range Often the underlying DCOM or WMI system of Windows throws an error code that starts with Before applying any instructions please exercise proper system administrator housekeeping. https://msdn.microsoft.com/en-us/library/aa394559(v=vs.85).aspx

What Is Wmi Error

Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies For Windows Vista and later, see here. You can add the following registry key to disable this feature of UAC. If you see entries similar to this, then the consistency check has failed: Copy (Wed Oct 12 14:17:14 2005): Failing Connecting to Namespace [root\default] with result [80041002] Note.

This error may be caused by many conditions, including the following: Provider is using a WMI DLL that does not match the .lib file used when the provider was built. You can also use the "contact support" feature from within your PRTG setup to send them additional diagnostic info that will hopefully help solve this issue. Failure to create an instance of or inherit from the __Win32Provider class to create the provider registration in the MOF file. WBEM_E_PROVIDER_LOAD_FAILURE 2147749907 (0x80041013) COM cannot locate a provider referenced Wmi Error Codes Add comment Created on Aug 16, 2016 6:30:21 PM by Wayne Byers (10) Permalink Votes:0 Your Vote: Up Down We have the same doubts as you have about using domain admin

I also monitored the system and application event logs with 15 minute intervals. Wmi Error Windows 7 DNS/WINS is not used in this setup so I added the device name/IP to the probe's hosts file and changed the Name/IP field to name in the PRTG device settings. One customer reported that he had two NICs running in teaming mode for a long time whithout any problems when suddenly this error came up. https://kb.paessler.com/en/topic/1093-my-wmi-sensors-show-errors-with-a-pe-code-what-does-that-mean In that case, you will need to contact Microsoft Product Support Services (PSS).

Quick fix: execute "netsh firewall set service RemoteAdmin enable" from command console at the monitored host (not the host on which the collector is running). Wmi Error Invalid Class Some options to resolve this may be: Ensure the Windows Management Instrumentation serviceis running. Instead, you must have Service Pack 2 (or a later service pack) installed in order to connect to remote machines running Windows Server 2003. Add comment Created on Nov 23, 2010 12:24:55 PM by Bruno Ruy (1) ●2 Permalink Votes:0 Your Vote: Up Down Hi, we also had this problem coming up and disappearing again.

  • No longer will the Macs in your network be segregated from the Windows users.
  • Eventually learned that I can enable the firewall but should make an exception for WMI-IN rule.
  • Although the Scriptomatic utility was designed as a way to help you write simple WMI scripts, the tool can also be used to diagnose problems with the WMI service.After downloading and
  • So this is not a PRTG implementation issue but purely some oddity with WMI.
  • Actual performance can be significantly less depending on network topology and WMI health of the target systems - we have seen configurations that could not go beyond 500 sensors (and even
  • Remember that PRTG uses the 32-bit powershell as default.

Wmi Error Windows 7

If the server on which PRTG is installed is part of a domain, whereas you are trying to monitor a target machine that is not part of the domain, please see https://kb.paessler.com/en/topic/14-what-can-i-do-about-connection-could-not-be-established-errors-on-my-wmi-sensors Another way would be to use the sensor’s “Alternative Query” in the WMI Compatibility options, if available. What Is Wmi Error See below for error when adding WMI Network Sensor: Failed to find valid network cards. Wmi Error 10 You can select alternate WMI namespaces from the drop-down list as a way to browse through the entire WMI Repository and see if the class can be found.If the class exists

The user must use a blank username/password and rely on default security. WBEM_E_CANNOT_BE_ABSTRACT 2147749989 (0x80041065) Class was made abstract when its parent class is not abstract. WBEM_E_AMENDED_OBJECT 2147749990 (0x80041066) First, why not just rebuild the Repository? Shows you how to set up Windows networking features, and how to install and set up basic networking hardware. You can, but there are some risks involved in wiping out and replacing the Repository. Wmi Error 0x80041003

The easiest way to do that is to search the .MOF files (typically found in the folder %windir%\System32\Wbem) for the name of the class you are having difficulty with. Tip: The bottlenecks for WMI monitoring are these two services: WmiPrvSE.exe lsass.exe which don't support the usage of multiple processors. Use at your own risk. This can be caused by low memory availability or excessive memory consumption by WMI. WBEM_E_TRANSACTION_CONFLICT 2147749997 (0x8004106D) Operation resulted in a transaction conflict. WBEM_E_FORCED_ROLLBACK 2147749998 (0x8004106E) Transaction forced a

Information about namespace security can be found on the Security tab in the WMI Control Properties dialog box. Wmi Error Fix Please also see our extensive WMI Troubleshooting Guide. Summary: Vista In Depth takes on the constant barrage of spam, spyware, viruses and other Net nasties.

Votes:2 Your Vote: Up Down Some of my WMI sensors in PRTG are down.

Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Query returned more than one row (code: PE038) w.i.p. Just select WMI-In option with the Domain profile value. Wmi Return Codes You are invited to get involved by asking and answering questions!

Also, many of the above commands do not echo a response after completion, so do not be alarmed if you do not notice any changes occurring after passing a command. However, if you suspect that the Windows Firewall is to blame you can find information about managing and configuring the firewall settings in the article I Married Bigfoot! On This Page My script doesn’t return any data I can’t connect to a remote computer I’m getting an 0x8004100E (“Invalid Namespace”) error I’m getting an 0x80041010 (“Invalid Class”) error I’m Vincent Add comment Created on Aug 20, 2012 8:08:51 AM by nolme (0) ●1 Permalink Votes:0 Your Vote: Up Down If WMITest shows Error 800706BA: In Windows Firewall enable port TCP

You can try to use the alternative query of a sensor if applicable. 0% Free Disk Space Windows 2008 One customer of ours found the following solution for this problem on Most likely you will never even know that the service had been stopped. The content you requested has been removed. In the Administrative Tools window, double-click Computer Management.

The property was inherited from a parent class. WBEM_E_UNEXPECTED 2147749917 (0x8004101D) Client made an unexpected and illegal sequence of calls, such as calling EndEnumeration before calling BeginEnumeration. WBEM_E_ILLEGAL_OPERATION 2147749918 Click "Connect". You may be experiencing unexplained errors such as "Empty result set", ox80041003, 0x80041017from the collector debug, WBEMTEST utility, or your custom application. We have also seen trouble with DNS/DHCP entries, directing the host name to the wrong IP address, resulting in this error - try using the explicit IP address as host setting

Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Path: HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\system Key: LocalAccountTokenFilterPolicy Value: 1 (DWORD) Please be warned that this disables some of the protection provided by UAC. I've added your solution to our Most common WMI errors article.