Home > Socket Error > Wsa Error 121

Wsa Error 121

Contents

Yupper there it plain as day:hmailserver.iniCode: Select all[Settings]
SAMaxTimeout=180
;
90 seconds is default
If I recall now I increased it to 180 from 90 to test i'm not sure I The default is 300 seconds for consistency with the spamd default setting of --timeout-child .This is a best-effort advisory setting, processing will not be abruptly aborted at an arbitrary point in Too many links were encountered in translating a pathname. This error is raised on a request (on an already opened and therefore reused connection) where the client does not get any response from the server after 8 tries.

Berkeley description: An operation was attempted on a non-blocking object that already had an operation in progress. The current Windows Sockets implementation does not support the Windows Sockets specification version requested by the application. Berkeley description: Too many open files. Top jimimaseye Moderator Posts: 4724 Joined: 2011-09-08 17:48 Re: Code: HM5157 WinSock error code is 10054 Quote Postby jimimaseye » 2014-08-02 22:19 Ok, I still stand mildly confused about your explanation.

Socket Error 10054

Now, my scantimes have dropped to just 3 seconds.Why is this relevant? The file's permission setting does not allow the specified access. Check whether you have a router configured in your network system (your WinSock implementation). It is normal for WSAEWOULDBLOCK to be reported as the result from calling connect on a nonblocking SOCK_STREAM socket, since some time must elapse for the connection to be established.

I should say WAS as I added some INI settings to adjust timeouts but not sure they help:viewtopic.php?p=132238#p132238I haven't looked back at the code to see if the ini settings for Winsock Errors Error Code Fixit! An object with an invalid ObjectLength field was specified in the QoS provider-specific buffer. Socket Error 10054 Connection Reset By Peer You need to call htons() to translate a constant value to network byte order before assigning it to the sin_port field in the sockaddr structure.

Any application that uses a blocking socket or calls any blocking functions must handle this error. Socket Error 10053 WSAELOOP 10062 Cannot translate name. This may be because the database files (for example, BSD-compatible HOSTS, SERVICES, or PROTOCOLS files) could not be found, or a DNS request was returned by the server with a severe Ignore it.

Specifically, v1.1 WinSock spec notes that this error occurs if the length of the buffer is too small. Socket Error 11004 Developer suggestions: Did you close a socket inadvertently in one part of an application without keeping another part notified? And yet look at the 'scantime'. Sales: 1.800.290.5054 - 1.210.308.8267 Support: 1.210.366.3993 Contact Us Copyright ©1996-2016 GlobalSCAPE, Inc.

  1. A socket already has a type (a protocol), and each sockaddr structure has an address family field to define its format.
  2. An example is using a broadcast address for sendto without broadcast permission being set using setsockopt(SO_BROADCAST).
  3. WinSock functions: WSACancelAsyncRequest() Additional functions: Berkeley sockets connect() returns this error on subsequent calls, after an initial call on a non-blocking socket.

Socket Error 10053

This documentation is archived and is not being maintained. Go to TOOLS > OPTIONS > GENERAL TAB and untick this option. Socket Error 10054 The v1.1 specification also lists connect(), although it does not allocate a descriptor. Socket Error Codes Linux Developer suggestions: Assume bind() will fail with this error.

A QoS error occurred due to lack of resources. Try a traceroute to the destination address to check that all the routers are functioning. WinSock functions: socket() See also: WSAEAFNOSUPPORT, WSAEPFNOSUPPORT WSAEREMOTE (10071) Too many levels of remote in path Berkeley description: Item is not local to the host. WinSock description: Almost same as Berkeley. Socket Error 10049

A connect request was made on an already-connected socket. The attempted operation is not supported for the type of object referenced. User suggestions: Things an application user can do to diagnose the error condition further, and/or remedy it. Developer suggestions: WSAStartup() failed, and you didn't detect it, or it wasn't called for the current task at all, or you called WSACleanup() too many times.

Generically, the error means the network system has run out of socket handles. Socket Error 10061 Connection Refused An invalid value was given for one of the arguments to a function. Either wait 20-30 minutes for it to time out or get somebody to shell into the mail server and stop the mail task that is running on the account.

An invalid QoS filter style was used.

The server will not delete this directory while there are files/folders in it. In some cases these errors are platform dependent. Berkeley description: Some invalid argument was supplied (for example, specifying an invalid level to the setsockopt() function). Winsock Error 10054 Fix NNTP Errors Error Code Fixit!

Enable debug logging to retrieve more information regarding this problem. WSASYSCALLFAILURE 10107 System call failure. Do not set non-zero timeout on non-blocking sockets to avoid this ambiguity (see Chapter 9 for more information). WinSock description: No equivalent.

Returned when a provider does not return SUCCESS and does not provide an extended error code. WSAENAMETOOLONG 10063 Name too long. Developer suggestion: Use the sample code fragment in the WSAStartup() documentation in the v1.1 specification, which demonstrates how an application negotiates a Windows Sockets specification version.